Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 112
Filtrar
2.
VideoGIE ; 9(3): 119-122, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38482469

RESUMO

Video 1The mass was identified at the upper- to mid-esophagus, 25 cm from the central incisors. No varices were seen on further examination of the esophagus. A 4-mm injector force needle was used to create a large submucosal injection using BlueBoost lifting agent proximal to the mass. A longitudinal mucosal incision was then made using the hybrid T-type electrocautery knife, 20 cm from the central incisors.The cutting current was the preset Endocut Q mode, and the coagulation setting was spray coag mode, effect 2 and 40 W.Next, tunnel creation by submucosal dissection was performed with a focus on keeping the submucosal space as clean as possible. Carbon dioxide was used for insufflation to prevent pneumoperitoneum.A smooth-surfaced oval mass was identified originating from the muscularis propria layer. Dissection was extended 2 cm distally beyond the mass. Next, resection of the mass was performed. First, the mucosal surface of the mass was dissected. Dissection began at the distal portion, proceeded to the left and right lateral borders, and then continued toward the proximal portion. The mass was dissected away from the muscularis propria.We focused on freeing the mass, ensuring this esophageal mass was intact throughout dissection. The attached bands of muscularis propria at the distal portion were carefully resected completely.Water irrigation was used at this time to ensure better visualization for resection. The remaining attached bands of muscularis propria were resected, ensuring complete en bloc resection. Afterward, the mass was suctioned into the cap and carefully retrieved as shown, and then sent to pathology for processing.The entire defect bed was inspected post-resection, and no perforation or bleeding was identified.The mucosal defect was completely closed with through-the-scope hemostatic clips in a longitudinal fashion beginning with approximation of the defect at the distal portion.

3.
ACG Case Rep J ; 10(12): e01229, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38130477

RESUMO

Pyloric gland adenomas (PGAs) are rare neoplasms found not only in the gastrointestinal tract but also in other extragastrointestinal organs. They have potential for malignant conversion, and early detection and removal is imperative to prevent invasive disease. PGAs prove difficult in management and surveillance given their rarity. However, increasing familiarity with histological appearance and use of advanced tools such as echoendosonography can bring greater understanding of their clinical history. We describe a unique case of a PGA detected within a hiatal hernia sac characterized with echoendosonography and highlight the need to develop surveillance protocols for these types of lesions.

4.
ACG Case Rep J ; 10(12): e01210, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38130479

RESUMO

Kaposi sarcoma (KS) is a pathological endothelial growth associated with human herpes virus-8 which primarily affects the skin. In HIV-negative men who have sex with men, the clinical presentation of KS resembles the classic form limited to cutaneous or multifocal disease. In this report, we present a unique case of a healthy 61-year-old man who has sex with men with an isolated gastrointestinal KS who does not meet criteria for any of the typical KS clinical variants. Proper follow-up and regular HIV screenings are needed to evaluate the potential progression course of the disease in these patients.

6.
VideoGIE ; 8(9): 340-341, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37719948

RESUMO

Video 1Endoscopic treatment of a Bouveret syndrome showing and describing the techniques and procedures involved.

7.
VideoGIE ; 8(8): 298-300, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37575135

RESUMO

Video 1Enhanced suction for removal of esophageal food impaction.

8.
VideoGIE ; 8(8): 304-306, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37575141

RESUMO

Video 1Natural orifice transendoscopic surgery as a rescue for a dislodged lumen-apposing metal stent after EUS-directed transgastric ERCP.

9.
Endoscopy ; 55(12): 1103-1114, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37463599

RESUMO

BACKGROUND: The first commercialized single-use duodenoscope was cleared by the US Food and Drug Administration in December 2019. Data regarding endoscopic retrograde cholangiopancreatography (ERCP) using a single-use duodenoscope are needed on a broader range of cases conducted by endoscopists with varying levels of experience in a wide range of geographic areas. METHODS: 61 endoscopists at 22 academic centers in 11 countries performed ERCP procedures in adult patients aged ≥ 18. Outcomes included ERCP completion for the intended indication, rate of crossover to a reusable endoscope, device performance ratings, and serious adverse events (SAEs). RESULTS: Among 551 patients, 236 (42.8 %) were aged > 65, 281 (51.0 %) were men, and 256 (46.5 %) had their procedure as an inpatient. ERCPs included 196 (35.6 %) with American Society for Gastrointestinal Endoscopy complexity of grades 3-4. A total of 529 ERCPs (96.0 %) were completed: 503 (91.3 %) using only the single-use duodenoscope, and 26 (4.7 %) with crossover to a reusable endoscope. There were 22 ERCPs (4.0 %) that were not completed, of which 11 (2.0 %) included a crossover and 11 (2.0 %) were aborted cases (no crossover). Median ERCP completion time was 24.0 minutes. Median overall satisfaction with the single-use duodenoscope was 8.0 (scale of 1 to 10 [best]). SAEs were reported in 43 patients (7.8 %), including 17 (3.1 %) who developed post-ERCP pancreatitis. CONCLUSIONS: In academic medical centers over a wide geographic distribution, endoscopists with varying levels of experience using the first marketed single-use duodenoscope had good ERCP procedural success and reported high performance ratings for this device.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Pancreatite , Adulto , Masculino , Humanos , Feminino , Colangiopancreatografia Retrógrada Endoscópica/métodos , Duodenoscópios/efeitos adversos , Endoscopia Gastrointestinal , Pancreatite/etiologia
11.
VideoGIE ; 8(3): 115-117, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36935808

RESUMO

Video 1Video of holmium laser lithotripsy procedure.

12.
Nat Commun ; 14(1): 109, 2023 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-36611024

RESUMO

Bile duct cancer is the second most common primary liver cancer, with most diagnoses occurring in the advanced stages. This leads to a poor survival rate, which means a technique capable of reliably detecting pre-cancer in the bile duct is urgently required. Unfortunately, radiological imaging lacks adequate accuracy for distinguishing dysplastic and benign biliary ducts, while endoscopic techniques, which can directly assess the bile duct lining, often suffer from insufficient sampling. Here, we report an endoscopic optical light scattering technique for clinical evaluation of the malignant potential of the bile duct. This technique employs an ultraminiature spatial gating fiber optic probe compatible with cholangioscopes and endoscopic retrograde cholangiopancreatography (ERCP) catheters. The probe allowed us to investigate the internal cellular composition of the bile duct epithelium with light scattering spectroscopy (LSS) and phenotypic properties of the underlying connective tissue with diffuse reflectance spectroscopy (DRS). In a pilot in vivo double-blind prospective study involving 29 patients undergoing routine ERCP procedures, the technique detected malignant transformation with 97% accuracy, showing that biliary duct pre-cancer can be reliably identified in vivo non-invasively.


Assuntos
Neoplasias dos Ductos Biliares , Colangiocarcinoma , Humanos , Estudos Prospectivos , Colangiopancreatografia Retrógrada Endoscópica/métodos , Ductos Biliares/diagnóstico por imagem , Neoplasias dos Ductos Biliares/diagnóstico por imagem , Ductos Biliares Intra-Hepáticos , Análise Espectral
13.
Scand J Gastroenterol ; 58(6): 664-670, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36519564

RESUMO

OBJECTIVES: Meticulous inspection of the mucosa during colonoscopy, represents a lengthier withdrawal time, but has been shown to increase adenoma detection rate (ADR). We investigated if artificial intelligence-aided speed monitoring can improve suboptimal withdrawal time. METHODS: We evaluated the implementation of a computer-aided speed monitoring device during colonoscopy at a large academic endoscopy center. After informed consent, patients ≥18 years undergoing colonoscopy between 5 March and 29 April 2021 were examined without the use of the speedometer, and with the speedometer between 29 April and 30 June 2021. All colonoscopies were recorded, and withdrawal time was assessed based on the recordings in a blinded fashion. We compared mean withdrawal time, percentage of withdrawal time ≥6 min, and ADR with and without the speedometer. RESULTS: One hundred sixty-six patients in each group were eligible for analyses. Mean withdrawal time was 9 min and 6.6 s (95% CI: 8 min and 34.8 s to 9 min and 39 s) without the use of the speedometer, and 9 min and 9 s (95% CI: 8 min and 45 s to 9 min and 33.6 s) with the speedometer; difference 2.3 s (95% CI: -42.3-37.7, p = 0.91). The ADRs were 45.2% (95% CI: 37.6-52.8) without the speedometer as compared to 45.8% (95% CI: 38.2-53.4) with the speedometer (p = 0.91). The proportion of colonoscopies with withdrawal time ≥6 min without the speedometer was 85.5% (95% CI: 80.2-90.9) versus 86.7% (95% CI: 81.6-91.9) with the speedometer (p = 0.75). CONCLUSIONS: Use of speed monitoring during withdrawal did not increase withdrawal time or ADR in colonoscopy. CLINICALTRIALS.GOV IDENTIFIER: NCT04710251.


Assuntos
Adenoma , Pólipos do Colo , Neoplasias Colorretais , Humanos , Adenoma/diagnóstico , Inteligência Artificial , Colonoscopia , Neoplasias Colorretais/diagnóstico , Fatores de Tempo
14.
Endosc Int Open ; 10(8): E1065-E1072, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35979031

RESUMO

Background and study aims Optical coherence tomography (OCT) is a new technology available for evaluation of indeterminate biliary strictures. It allows under-the-surface visualization and preliminary studies have confirmed standardized characteristics associated with malignancy. The aim of this study is to evaluate the first interobserver agreement in identifying previously agreed upon OCT criteria and diagnosing of malignant versus benign disease. Patients and methods Fourteen endoscopists were asked to review an atlas of reference clips and images of eight criteria derived from expert consensus A total of 35 de-identified video clips were then evaluated for presence of the eight criteria and for final diagnosis of malignant versus benign using the atlas as reference Intraclass correlation (ICC) analysis was done to evaluate interrater agreement. Results Clips of 23 malignant lesions and 12 benign lesions were scored. Excellent interobserver agreement was seen with dilated hypo-reflective structures (0.85) and layering effacement (0.89); hyper-glandular mucosa (0.76), intact layering (0.81), and onion-skin layering (0.77); fair agreement was seen with scalloping (0.58), and thickened epithelium (0.4); poor agreement was seen with hyper-reflective surface (0.36). The diagnostic ICC for both neoplastic (0.8) and non-neoplastic (0.8) was excellent interobserver agreement. The overall diagnostic accuracy was 51 %, ranging from 43 % to 60 %. Conclusions Biliary OCT is a promising new modality for evaluation of indeterminate biliary strictures. Interobserver agreement ranged from fair to almost perfect on eight previously identified criteria. Interobserver agreement for malignancy diagnosis was substantial (0.8). Further studies are needed to validate this data.

15.
Gastrointest Endosc ; 96(5): 764-770, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35724696

RESUMO

BACKGROUND AND AIMS: During endoscopy, droplets with the potential to transmit infectious diseases are known to emanate from a patient's mouth and anus, but they may also be expelled from the biopsy channel of the endoscope. The main goal of our study was to quantify droplets emerging from the biopsy channel during clinical endoscopy. METHODS: A novel light-scattering device was used to measure droplets emanating from the biopsy channel. An endoscopy model was created, and in vitro measurements were carried out during air insufflation, air and water suctioning, and the performance of biopsy sampling. Similar measurements were then made on patients undergoing endoscopy, with all measurements taking place over 2 days to minimize variation. RESULTS: During in vitro testing, no droplets were observed at the biopsy channel during air insufflation or air and water suctioning. In 3 of 5 cases, droplets were observed during biopsy sampling, mostly when the forceps were being removed from the endoscope. In the 22 patients undergoing routine endoscopy, no droplets were observed during air insufflation and water suctioning. Droplets were detected in 1 of 11 patients during air suctioning. In 9 of 18 patients undergoing biopsy sampling and 5 of 6 patients undergoing snare polypectomies, droplets were observed at the biopsy channel, mostly when instruments were being removed from the endoscope. CONCLUSIONS: We found that the biopsy channel may be a source of infectious droplets, especially during the removal of instruments from the biopsy channel. When compared with droplets reported from the mouth and anus, these droplets were larger in size and therefore potentially more infectious.


Assuntos
Doenças Transmissíveis , Endoscópios , Humanos , Endoscopia Gastrointestinal , Biópsia , Endoscopia , Água
16.
Gastrointest Endosc ; 95(4): 711-716, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34915035

RESUMO

BACKGROUND AND AIMS: EUS is increasingly used to evaluate patients with liver disease, but its role in assessing hepatic steatosis has not been reported. The goal of our study was to assess the accuracy of EUS for diagnosing hepatic steatosis. METHODS: We identified all patients who underwent EUS-guided liver biopsy sampling at our institution. All digitally stored EUS liver images were reviewed by a single radiologist, who rated the severity of liver echogenicity using a 4-point US scale. Liver biopsy specimens for all study patients were reviewed by a single liver pathologist, who rated them for steatosis and fibrosis using Nonalcoholic Steatohepatitis Clinical Research Network criteria. Receiver operator characteristic curves were used to assess the diagnostic accuracy of EUS for hepatic steatosis for all patients and in a subgroup analysis for obese and nonobese patients. RESULTS: During the study period, 76 patients underwent EUS-guided liver biopsy sampling. The average age of study patients was 56.5 years, 50% were women, and 43.2% were obese. The accuracy for EUS for the diagnosis of hepatic steatosis was .8 (95% confidence interval [CI], .7-.89). The accuracy of EUS for the diagnosis of hepatic steatosis in obese patients was .93 (95% CI, .8-.99) and in nonobese patients was .69 (95% CI, .54-.83). For obese patients, EUS had a positive predictive value of 89.7% and a negative predictive value of 75%. The finding of course echotexture on EUS had an accuracy of 79% for the diagnosis of grade 3 fibrosis or cirrhosis. CONCLUSIONS: EUS is a useful tool for the diagnosis of hepatic steatosis, particularly in obese patients in whom abdominal US has modest accuracy.


Assuntos
Técnicas de Imagem por Elasticidade , Hepatopatia Gordurosa não Alcoólica , Biópsia , Técnicas de Imagem por Elasticidade/métodos , Feminino , Fibrose , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico por imagem , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Obesidade/complicações , Estudos Prospectivos
17.
J Clin Gastroenterol ; 56(2): e94-e97, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32040050

RESUMO

BACKGROUND: Visual characteristics seen during digital single-operator cholangioscopy (DSOC) have not been validated. The aim of this 2-phase study was to define terminology by consensus for the visual diagnosis of biliary lesions to develop a model for optimization of the diagnostic performance of DSOC. MATERIALS AND METHODS: In phase 1 (criteria identification), video-cholangioscopy clips were reviewed by 12 expert biliary endoscopists, who were blinded to the final diagnosis. Visual criteria were consolidated into the following categories: (1) stricture, (2) lesion, (3) mucosal features, (4) papillary projections, (5) ulceration, (6) abnormal vessels, (7) scarring, (8) pronounced pit pattern.During the second phase (validation), 14 expert endoscopists reviewed DSOC (SpyGlass DS, Boston Scientific) clips using the 8 criteria to assess interobserver agreement (IOA) rate. RESULTS: In phase 1, consensus for visual findings were categorized into 8 criteria titled the "Monaco Classification." The frequency of criteria were: (1) presence of stricture-75%, (2) presence of lesion type-55%, (3) mucosal features-55%, (4) papillary projections-45%, (5) ulceration-42.5%, (6) abnormal vessels-10%, (7) scarring-40%, and (8) pronounced pit pattern-10%. The accuracy on final diagnosis based on visual impression alone was 70%.In phase 2, the IOA rate using Monaco Classification criteria ranged from slight to fair. The presumptive diagnosis IOA was fair (κ=0.31, SE=0.02), and overall diagnostic accuracy was 70%. CONCLUSIONS: The Monaco classification identifies 8 visual criteria for biliary lesions on single-operator digital cholangioscopy. Using the criteria, the IOA and diagnostic accuracy rate of DSOC is improved compared with prior studies.


Assuntos
Colestase , Variações Dependentes do Observador , Colestase/diagnóstico por imagem , Classificação/métodos , Constrição Patológica/diagnóstico , Humanos
18.
Surg Endosc ; 36(4): 2418-2429, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33977378

RESUMO

BACKGROUND: The optimal timing of biliary drainage by endoscopic retrograde cholangiopancreatography (ERCP) for patients with acute cholangitis remains controversial. The aim of our study was to determine if ERCP performed within 6 or 12 h of presentation was associated with improved clinical outcomes. METHODS: Medical records for all patients with acute cholangitis who underwent ERCP at our institution between 2009 and 2018 were reviewed. Outcomes were compared between those who underwent ERCP within or after 12 h using propensity score framework. Our primary outcome was length of hospitalization. Secondary outcomes included in-hospital mortality, adverse events, ERCP failure, length of ICU stay, organ failure, recurrent cholangitis, and 30-day readmission. In secondary analysis, outcomes for ERCP done within or after 6 h were also compared. RESULTS: During study period, 487 patients with cholangitis were identified, of whom 147 had ERCP within 12 h of presentation. Using propensity score matching, we selected 145 pairs of patients with similar characteristics. Length of hospitalization was similar between ERCP within or after 12 h (135.9 vs 122.1 h, p 0.094). No difference was noted in mortality, ERCP failure, adverse events, need and length of ICU stay, and recurrent cholangitis. However, 30-day readmission rates were lower when ERCP within 12 h (7.6 vs 15.2, p 0.042). No significant difference was noted in aforementioned outcomes between ERCP performed within or after 6 h. CONCLUSIONS: ERCP performed within 6 h or 12 h of presentation was not associated with superior clinical outcomes, however, may result in reduced re-hospitalization.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Colangite , Doença Aguda , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Colangite/etiologia , Humanos , Tempo de Internação , Pontuação de Propensão , Estudos Retrospectivos , Resultado do Tratamento
19.
Gastrointest Endosc ; 95(1): 80-89, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34352256

RESUMO

BACKGROUND AND AIMS: Stent misdeployment (SM) has hindered the dissemination of EUS-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction (GOO) management. We aimed to provide a classification system for SM during EUS-GE and study clinical outcomes and management accordingly. METHODS: This is a retrospective study involving 16 tertiary care centers (8 in the United States, 8 in Europe) from March 2015 to December 2020. Patients who developed SM during EUS-GE for GOO were included. We propose classifying SM into 4 types. The primary outcome was rate and severity of SM (per American Society for Gastrointestinal Endoscopy lexicon), whereas secondary outcomes were clinical outcomes and management of dislodgement according to the SM classification type, in addition to salvage management of GOO after SM. RESULTS: From 467 EUS-GEs performed for GOO during the study period, SM occurred in 46 patients (9.85%). Most SMs (73.2%) occurred during the first 13 EUS-GE cases by the performing operators. SM was graded as mild (n = 28, 60.9%), moderate (n = 11, 23.9%), severe (n = 6, 13.0%), or fatal (n = 1, 2.2%), with 5 patients (10.9%) requiring surgical intervention. Type I SM was the most common (n = 29, 63.1%), followed by type II (n = 14, 30.4%), type IV (n = 2, 4.3%), and type III (n = 1, 2.2%). Type I SM was more frequently rated as mild compared with type II SM (75.9% vs 42.9%, P = .04) despite an equivalent rate of surgical repair (10.3% vs 7.1%, P = .7). Overall, 4 patients (8.7%) required an intensive care unit stay (median, 2.5 days). The median length of stay was 4 days after SM. CONCLUSIONS: Although SM is not infrequent during EUS-GE, most are type I, mild/moderate in severity, and can be managed endoscopically with a surgical intervention rate of approximately 11%.


Assuntos
Endossonografia , Obstrução da Saída Gástrica , Obstrução da Saída Gástrica/cirurgia , Gastroenterostomia , Humanos , Estudos Retrospectivos , Stents
20.
Ann Transl Med ; 9(18): 1408, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34733960

RESUMO

BACKGROUND: This study compares standard of care (SOC) open and robotic D2-gastrectomy for locally advanced gastric cancer (LAGC) in the Western context of low disease prevalence, reduced surgical volume, and neoadjuvant chemotherapy (NAC). We hypothesized that robotic gastrectomy (RG) after NAC reduces treatment burden for LAGC across multiple outcome domains vs. SOC. METHODS: Single institution, interrupted time series comparing SOC (2008-2013) for LAGC (T2-4Nany/TanyN+) vs. NAC + RG (2013-2018). Treatment burden was a composite metric of narcotic consumption, oncologic efficacy, cumulative morbidity, and 90-day resource utilization. Predictors were evaluated via multivariate modeling. Learning curve analysis was done using CUSUM. RESULTS: After exclusions, 87 subjects with equivalent baseline characteristics, aside from male sex, were treated via SOC (n=55) or NAC + RG (n=32). All four domains of treatment burden were significantly reduced in the NAC + RG cohort compared to SOC (P=0.003). The odds ratio for excess treatment burden in the NAC/RG was 0.23 (95% CI: 0.07-0.72, P=0.0117) vs. SOC upon multivariable modeling, whereas the extent of resection (total/subtotal), tumor size, T-stage, sex, and early learning curve had no effect. Differences in treatment burden persisted in subgroup analysis for NAC (n=51). CONCLUSIONS: NAC + RG was associated with decreased treatment burden relative to SOC for LAGC. Frequencies of unfavorable hospitalization, adverse oncological outcomes, major morbidity, and narcotic consumption all decreased in this interrupted time series.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...